Generator Repair for Standby and Prime Sets
A set that will not start, starts and stops, or will not take the load is a problem you usually find at the worst moment. The quickest repairs come from a clear description of what the set did and what the panel said.
Repair work is priced on time, parts and access. We can’t give you a figure, but we can help you describe the fault well enough for an engineer to come with the right parts.
- Note first
- The alarm or fault code on the panel
- Also note
- Make, model and running hours
- Covers
- Diesel, gas, standby and prime sets
Before you call: what to write down
Are you looking at a set that has an alarm showing right now? Before anyone resets it, take a photo of the controller screen. A lot of panels clear the fault when they are reset, and the code is often the best clue an engineer gets.
- The fault or alarm on the controller, word for word.
- The rating plate: make, model, serial number and size in kVA.
- Running hours from the hour meter.
- What happened: failed to start, stopped under load, would not transfer, smoke, a leak.
- When it was last serviced, and by whom if you know.
Put all of it in the notes on the form. It saves a wasted first visit, and on a set that is down that matters more than anything else.
Where faults tend to come from
There is no official list of generator faults, so treat this as a guide to what engineers will usually look at first rather than a diagnosis. In a lot of cases a standby set that fails does so because of something that ages while it sits.
| What you see | Where the engineer will often start |
|---|---|
| Will not crank or cranks slowly | Starting batteries, the charger and connections |
| Cranks but will not fire | Fuel supply, filters and the condition of the stored fuel |
| Starts, then shuts down | The alarm that caused the shutdown: temperature, oil pressure, overspeed |
| Runs but will not take the load | The changeover panel and the signal between it and the set |
| Black smoke or wet exhaust after test runs | Light-load running and the need for a load bank test |
If fuel is the cause, the engineer may suggest cleaning it. Our fuel polishing page explains what that involves.
Keep people away from live parts
It’s very important not to open panels or try a restart on a set you are not trained to work on. A standby set can start on its own when the mains drops, and the changeover panel carries mains and generator supplies side by side. The Electricity at Work Regulations 1989 put duties on whoever controls the system to prevent danger, and HSE’s HSR25 guidance covers work on or near live equipment.
So the useful thing you can do is make the set safe to approach, record what you can see from the controller, and let the engineer do the rest.
How a repair is usually priced
Most firms charge for the visit, the time on site and the parts. Some quote a fixed fee for a diagnosis visit, then quote the repair once they know what is wrong. Ask which way they work before they set off.
If the set is on a maintenance contract, check what the contract says about call-outs first. If it isn’t, a repair is a good moment to ask for a quote for planned servicing too, because the same faults tend to come back on a set nobody is looking after.
How the job gets done
Describe the fault
Postcode, the alarm text, the set size and what it did. Photos can follow by email.
First look
The engineer reads the alarm and plate details and decides which parts to bring.
Diagnosis
They confirm the fault on site, or from the details, and tell you what it needs.
Repair quote
You get the price for the repair in writing before the work goes ahead.
Repairs and breakdowns: questions
Should I reset the alarm before the engineer comes?
Photograph the controller first. Many panels lose the fault record on reset, and the code is often what tells the engineer which parts to bring.
Can you send someone today?
Nobody can promise a time without knowing the fault and the location, and the engineer will tell you when they can attend. Mark the form “This week: the set is down or alarming” so it is clear how urgent it is.
Do you cover gas generators?
We look for an engineer who works on gas sets. Work on the gas supply usually needs a Gas Safe registered engineer, so give the fuel type on the form.
Is it worth repairing an old set?
That depends on the fault, the parts and what the set protects. A good engineer will tell you plainly if a repair is poor value, and can quote for a replacement at the same time if you ask.
What information helps most?
The alarm text, the rating plate (make, model, kVA) and the running hours. With those, an engineer can often narrow the fault down before arriving.
Ask for a quote for your generator
We look for one service engineer who works in your area and tell you who they are before any of your details go to them. You pay nothing for this.
- You tell us where the set is and what it needs.
- We name an engineer who covers your site.
- You say yes or no before your details are passed on.
- They quote in writing, directly to you.