Planned servicing, repairs and load bank tests for standby sets, for hospitals, data rooms, offices and farms across the UK.

Get a quote

One set, one year

A public tender for standby generator maintenance set the minimum at two visits a year for every set, plus a long test under load. It is a fair benchmark for your own plan.

Example service year for one standby generatorTwelve months in a row. A major service in March, a minor service in September, and a four-hour load bank test at up to 110 percent of full load in March alongside the major service.JanFebMarAprMayJunJulAugSepOctNovDecMajor serviceVisit one of twoLoad bank test4 hours, up to 110% of full loadMinor serviceVisit two of two
Example timing. The pattern (two visits a year, one major and one minor, and a yearly four-hour load bank test) is the minimum written into a public sector tender for standby sets. When the visits fall is agreed with your engineer.

Sites that depend on standby power

Hospitals, clinics and care homes

Emergency power for life-safety and clinical loads. NHS sites follow HTM 06-01 in England and SHTM 06-01 in Scotland, and the engineer should know it.

Data and comms rooms

A set behind the UPS that has to start and carry the room every time. Load bank tests and transfer tests matter most here.

Offices and commercial buildings

Often one set in a yard or basement that nobody has looked at since the fit-out. A planned service year puts that right.

Farms and rural businesses

Ventilation, milking and cold stores on long rural lines. Fuel stored on a farm in England follows its own oil storage rules.

The rules change at the border

If you look after sites in more than one part of the UK, you may find the fuel and healthcare rules differ between them. The engineering is the same; the paperwork is not.

The table shows the main differences we see. Your engineer should work to the version that applies where the set stands. We have pages for London and Scotland, the two places people search for most.

WhereFuel storageNHS emergency power
EnglandOil Storage Regulations 2001HTM 06-01
ScotlandSEPA oil storage rulesSHTM 06-01
Farms in EnglandAgricultural fuel oil rulesNot applicable

What moves the price of a service

There isn’t a published rate for generator servicing. Engineers price each set once they know its size, how many there are, how easy they are to reach, whether the work has to happen out of hours and what state the fuel is in.

So rather than guess at a figure, our scope builder lets you set those things down once. It gives you a written brief to send with your request, and every engineer then quotes against the same thing.

Open the scope builder, then send the brief with your request.

Questions facilities teams ask

What does a generator servicing company do?

It keeps standby and prime sets ready to run: planned service visits, repairs, load bank tests, fuel care and work on the changeover panel.

How often should our standby generator be serviced?

One public tender set the minimum at two visits a year per set, one major and one minor, plus a yearly four-hour load bank test (public tender, Contracts Finder). See maintenance contracts.

Do we have a legal duty to maintain it?

The Electricity at Work Regulations 1989 require electrical systems to be maintained, so far as is reasonably practicable, to prevent danger. Your standby set and its changeover are part of that system.

Can you give us a price?

No, because no official body publishes one and engineers price each set after a survey. Our scope builder turns your sets and visits into a written brief so the quotes you get are like for like.

Does the fuel tank need a bund?

Usually, in England. In England, oil stored above ground at a business in a container over 200 litres usually needs secondary containment, such as a bund holding 110% of the tank. There are exemptions, for example some tanks inside a building that would hold a leak (Control of Pollution (Oil Storage) (England) Regulations 2001). Scotland has its own rules (SEPA).

Do you cover gas-fuelled sets?

We look for an engineer who works on gas sets. Gas work usually needs a Gas Safe registered engineer, so give the fuel on the form.

Sources for this page

More on fuel, ratings and sizing on our Blog.

Ask for a quote for your generator

We look for one service engineer who works in your area and tell you who they are before any of your details go to them. You pay nothing for this.

  1. You tell us where the set is and what it needs.
  2. We name an engineer who covers your site.
  3. You say yes or no before your details are passed on.
  4. They quote in writing, directly to you.

Step 1 of 3

Where is the generator?
Get a quote